Skip to content

Flush mount

Rail, cleat and clamp sets that fix panels parallel to metal-sheet roofs, penetrative or non-penetrative.

Flush mount on IBR: cleats on the ribs carry the rail; end and mid clamps hold the modules.

Anodised as standard
10 µm
Every aluminium part is AL6005-T5, anodised to 10 µm as standard, not mill finish. Fasteners are SUS304 stainless steel.
Roof pitch
0° to 30°
Above 30°, a project-specific certificate
Interface spacing
1.5 m
Maximum, under the conditions in each manual
Wind regions
A to D
32 to 44 m/s, 50-year recurrence
Warranty
20 years
Aluminium and SUS304 parts, C1 to C4

Where it fits

Installers and EPC contractors fitting arrays on IBR, Klip-Lok and Saflok, corrugated, standing seam and Novotexi 440 sheeting, at roof slopes from 0° to 30°.

  • IBR

    LS-RP-01

    IBR cleat kit with EPDM seal and four self-tapping screws: fixed (LMS-IBR1-KIT) or adjustable (LMS-IBR2-KIT).

  • Klip-Lok / Saflok 410 and 700

    LS-RP-02

    Saflok 410/700 cleat (LMS-KL1-KIT) or Saflok mini-rail clamp kit (LMS-KL1-MR-KIT). No roof penetration.

  • Corrugated

    LS-RP-03

    Corrugated mini-rail kit (LMS-COR-MR-KIT, L80 H77) or corrugated L-bracket kits, portrait or landscape.

  • Standing seam

    LS-RP-04

    Standing seam multi clamp kit (LMS-SS-KIT). No roof penetration.

  • Novotexi 440

    LS-RP-05

    Novotexi 440 cleat (LMS-NVT-KIT) or Novotexi 440 mini rail.

What is in the kit

Choose the roof. The model, the drawing, the parts and their codes change with it. Select any part for its material and finish.

Roof
Representative model of the flush mount kit on IBR, assembled
Drag to rotate, select a part for its code
Representative model
Parts in the kit, with catalogue codes. Select a part to show it in the model.
ItemDescriptionCode
1LMS-EC30-35-KIT-BP
2LMS-IC30-35-KIT-BP
3LMS-PRO-RAILH
4LMS-IBR1-KIT
5LMS-RN-M8x20-KIT
6LMS-PRO-RAILH-SP-KIT

Select a part, in the list or in the model, for its code, material and finish.

A representative model for reading the assembly, not a design drawing. PV modules are shown for reference and are not part of the kit. Quantities are set for each project.

Configurations

Three ways the kit is built, one per roof, each with its own manual and limits.

More in this family

  • Klip-Lok full-rail solution

    Full rail on Klip-Lok sheeting, with more airflow under the panels.

    • Modules on Klip-Lok full rail, beside a walkway
    • A rail clamp on Klip-Lok sheeting
    • Full rails laid across the roof before the modules
  • Hanger bolt and L-bracket full rail

    A full-rail landscape system on roof sheeting, for landscape layouts where mini rails are not possible.

  • Novotexi 440 mini rail

Specifications for these three systems are in the Lumasol product catalogue (PDF, 2.0 MB).

Specification

From the Lumasol installation manual and product catalogue. Each system is designed for its project and ships with a detailed installation guide.

Compare flush mount with the other kit families
Flush mount specification
MaterialsAL6005-T5 aluminium rails, clamps, cleats and mini-rails. SUS304 stainless hardware in splice and clamp kits.
FinishAluminium anodised to 10 µm. Splice bolts and clamp bonding pins pierce the anodising to bond rails and modules.
Design basisWind regions A to D (32 to 44 m/s, 50-year recurrence). Guidance up to 20 m installation height; above that, a project-specific engineering certificate.Penetrative system assessed for terrain categories C and D. Non-penetrative system assessed for C, with spacing factors for A, B and D.
Roof pitch0° to 30°.Full 1.5 m interface spacing up to 18° roof tilt (penetrative) or 10° (non-penetrative).
Corrosion classAnodised aluminium and SUS304 stainless steel: 20 years in C1 to C3 and in C4, not warranted in C5. Screws (1022A, class 3): 20 years in C1 to C3.Reduce interface spacing by 5% in C4; the penetrative manual gives 25% for C5.
Interface spacingUp to 1.5 m.Penetrative: roof height to 20 m, roof tilt to 18°, internal roof zone, terrain C or D, clamp pull-out at least 2.5 kN. Rail overhang up to 40% of the last span.
Modules30 mm and 35 mm frames; adjustable end clamp for 30 to 45 mm.Penetrative 1.5 m spacing assumes modules up to 2278 × 1134 mm and 30 kg.
FasteningClamps, splices and M8 rail bolts 16 to 20 N·m.Penetrative cleats: four self-tapping screws with bonded washers at 300 RPM maximum.

Materials and corrosion by site

  • Rails, clamps, cleats and brackets: AL6005-T5 aluminium, anodised to 10 µm.
  • Bolts, rail nut bolts and splice hardware: SUS304 stainless steel.
  • Penetrative fixings seal with EPDM and bonded washers.
  • Splice bolts, clamp bonding pins and earthing clips pierce the anodising, so rails and module frames are bonded electrically.
  • Rib clamps can sit directly on most roof sheets; confirm the sheet's compatibility with anodised aluminium with its manufacturer.
Warranty and interface spacing by ISO 9223 corrosion class
Site classAluminium and SUS304 partsScrews (1022A, class 3)EPDM and other non-metallic partsInterface spacing
C1 to C3Inland20 years20 years3 yearsAs designed, up to 1.5 m
C4Coastal or industrial20 yearsNot warranted3 yearsReduce by 5% (1.425 m at most)
C5SevereNot warrantedNot warranted3 yearsReduce by 25% where the manual gives it (penetrative and L-bracket)
  • Classes to ISO 9223. Warranty from delivery, with the product registered within 30 days of purchase.
  • Where a site's class is uncertain, treat it as the higher class and confirm it with Lumasol.
Corrosion classes and the full warranty table

Spacing and design basis

The conditions each manual sets for the full 1.5 m interface spacing. The column for the roof chosen above is marked.

Interface spacing conditions by configuration
ConditionIBR cleat (penetrative)Chosen roofRib clamp (non-penetrative)L-bracket (corrugated)
Maximum interface spacing1.5 m1.5 m1.5 m
Roof heightUp to 20 mUp to 20 mUp to 20 m
Roof tiltUp to 18°Up to 10°Up to 10°
Roof zoneInternal roof zoneZone HZone H
Terrain categoryC or DC. Factors for A (90%), B (95%) and D (106%)C or D
Clamp pull-outAt least 2.5 kNAccredited sheets, or an on-site pull-out testAt least 2.5 kN
ModulesUp to 2278 × 1134 mm and 30 kg——
C4 siteReduce spacing by 5%Reduce spacing by 5%Reduce spacing by 5%
C5 siteReduce spacing by 25%Not givenReduce spacing by 25%
Rail end overhangUp to 40% of the last spanUp to 40% of the last spanUp to 40% of the last span
  • All three systems suit roof slopes from 0° to 30° and installation heights up to 20 m; above 20 m a project-specific engineering certificate is needed.
  • Outside any of these limits the spacing is reduced. Confirm it with Lumasol before installing.
  • At 1.5 m spacing, the rail can overhang the last interface by up to 600 mm.

Installation

The sequence from the Lumasol manual, for the IBR configuration. The manual is the reference on site.

  1. Step 1: Plan the layout

    • Confirm the wind region, terrain category, ISO 9223 class, roof height (up to 20 m) and slope (0° to 30°).
    • Allow at least 18 mm between modules down the slope; set the rails about ½ to ¾ of the module height apart.
    • Take the clamping zone from the module manufacturer's manual.
  2. Step 2: Fix the roof interface

    • Fix each cleat to the rib with four self-tapping screws with bonded washers: 3/8" hex socket, no more than 300 RPM, screws square to the sheet.
    • Tighten until the washer grips for a watertight seal, without over-tightening. Minimum pull-out 2.5 kN per clamp.
    • Set the cleats out in a straight line.
  3. Step 3: Fit the rails

    • U-channel facing up. Bolt each rail to its roof clamps at 16 to 20 N·m; every rail sits on at least two interfaces.
    • Join rails with the splice about ¼ span from a support, never over a support or at mid-span. Splice bolts 16 to 20 N·m; they pierce the anodising to bond the rails.
    • Keep the rail end overhang within 40% of the last span.
  4. Step 4: Clamp the modules

    • Fix the first module with an end clamp, lightly. Lift it slightly, slide in mid clamps with earthing clips, then place the next module.
    • Set the end clamp for 30 or 35 mm frames with its two holes. Earthing clips are single use.
    • Tighten every clamp to 16 to 20 N·m once the modules are in their final position.
  5. Step 5: Earth the array

    • One grounding lug per rail row, on M8 × 25 bolts at 16 to 20 N·m.
    • Earthing cable up to 35 mm², clamped with the M8 × 20 bolt at 8 to 12 N·m.
    • Check the resistance between the rail and the conductor.
Torques
FixingCodesTorque
End and mid clampsLMS-EC30-35-KIT-BP, LMS-IC30-35-KIT-BP16 to 20 N·m
Rail to roof clamp, M8LMS-IBR1-KIT, LMS-IBR2-KIT, LMS-KL1-KIT16 to 20 N·m
Rail splice boltsLMS-PRO-RAILH-SP-KIT16 to 20 N·m
Grounding lug, M8 × 25LMS-EGL-KIT16 to 20 N·m
Earthing cable bolt, M8 × 20LMS-EGL-KIT8 to 12 N·m

Stainless fasteners can gall. Apply force evenly along the thread, use power tools at low speed, and avoid impact drivers.

Tools

  • Screwdriver
  • Drill bits for M8 bolts
  • Torque spanner
  • 5 m tape
  • Marker pen
  • String line
Mounting Solar Panels onto IBR Roof SheetingThe video loads from YouTube, which sets its own cookies.
Download Flush mount, penetrative: installation manualPDF, 1.9 MB

Flush mount or tilt mount

The nearest kit in the range, side by side, from the two manuals.

Tilt mount specifications
Flush mount compared with tilt mount
FeatureFlush mountTilt mount
Panel angleParallel to the roof5°, 10° or 20° above the roof, set by the rear leg kit
RoofsIBR, Klip-Lok / Saflok, corrugated, standing seam, Novotexi 440IBR and corrugated, Klip-Lok / Saflok, concrete flat roofs, wooden purlins, Novotexi 440
Full 1.5 m spacingRoof tilt up to 18° (penetrative) or 10° (non-penetrative)Roof tilt plus panel tilt up to 5°, wind region A or B
Roof height for full spacingUp to 20 mUp to 15 m
Clamp pull-out for full spacingAt least 2.5 kNAt least 3.5 kN
RailPRO Rail H, or Rail 47 on L-bracketsPRO Rail 47
Choose it whenThe roof's own pitch and direction suit the arrayThe roof is flat or low-pitch and the panels need more angle than it gives

Technical questions

What roof pitch does the flush system suit?

Roof slopes from 0° to 30°. The full 1.5 m interface spacing applies up to 18° roof tilt for the penetrative system and up to 10° for the non-penetrative system.

When can roof clamps be spaced at 1.5 m?

Penetrative: roof height up to 20 m, roof tilt up to 18°, panels in the internal roof zone, terrain category C or D, clamp pull-out of at least 2.5 kN, and panels no larger than 2278 × 1134 mm and 30 kg. Non-penetrative: roof height up to 20 m, roof tilt up to 10°, and the array in Zone H. Outside these limits the spacing is reduced; confirm it with Lumasol before installing.

How are the penetrative IBR clamps fixed and sealed?

Each clamp is fixed to the roof sheet with four self-tapping screws with bonded washers, tightened until the washer grips to give a watertight seal. Use a 3/8" hex socket bit at no more than 300 RPM. The IBR cleat kits include an EPDM seal. Minimum pull-out is 2.5 kN per clamp.

Which roof sheets is the non-penetrative clamp accredited for?

Saflok 700, Saflok 410 and Lysaght Klip-Lok 305 (standing seam). If the sheet brand and model cannot be identified or is not on that list, Lumasol recommends an on-site pull-out capacity test.

Which panel frames fit?

The standard end and inter clamp kits take 30 mm and 35 mm frames; the end clamp has two holes to switch between them and ships pre-set for 30 mm. The adjustable end clamp kit (LMS-AEC30-45-KIT) covers 30 to 45 mm frames.

What changes on a coastal or industrial site?

Check the site class to ISO 9223. In C4, reduce interface spacing by 5%. The penetrative manual also gives a 25% reduction for C5. Anodised aluminium and SUS304 parts carry 20 years in C1 to C4 but are not warranted in C5; screws are warranted only in C1 to C3.

All projects
Truda Foods, Pietermaritzburg, 2,840 kWp, flush mount on metal sheeting
Truda Foods, Pietermaritzburg2,840 kWp, KwaZulu-Natal
Other projects on this kit
ProjectSite typeProvince or countrySystem size
Ndwedwe BoxerRooftopKwaZulu-Natal246.4 kWp
Athlone Shopping CentreRooftopKwaZulu-Natal239.4 kWp

Quote a flush mount kit