The same handful of mistakes come up again and again, on roofs and on ground mounts.

By the Lumasol technical team. Last updated .

Rows of full rails on hanger bolts and L-brackets running up a red corrugated roof, before the modules go on
Full rails on hanger bolts and L-brackets across a corrugated roof, before the modules go on

Key points

  • Roof mounts: brackets that miss the purlin or rafter, tile hooks resting on the tile, the wrong method for the roof sheet, no allowance for thermal expansion, and panels clamped outside the clamping zones.
  • Ground mounts: no soil check before choosing the foundation, uneven ground that isn't graded first, and loose assembly.
  • Both: wrong torque. Use a torque wrench and the torque in the manual.
  • Almost every issue is covered in the installation manual, for the structure and for the panels.

Roof mounts

Missing the purlin or rafter

Some clamps are designed to be secured to the roof sheeting itself, usually with four screws for pull-out strength, and that is perfectly normal. The problem is with brackets designed to go through the sheet into the substructure, such as L-brackets and hanger bolts. When the installer misses the purlin or rafter with the single fixing, it looks secure from the roof but it can pull out under wind load.

See: Flush mount kitPenetrative installation manualRails and componentsL-bracket full rail installation manual

Tile hooks resting on the tile

A correctly installed hook sits between two courses of tiles without putting pressure on the tile below. If it does bear on the tile, years of gusts flex the hooks and crack the tiles they rest on. Installers standing on the mounting structure crack tiles too.

See: Tile and slate kitPRO tile roof installation manual

Wrong method for the roof sheet

For South African roofs, IBR brackets should have rubber seals and never be secured in the valleys. Klip-Lok should be clamped to the ribs without drilling.

See: Flush mount kitPenetrative installation manualNon-penetrative installation manual

No allowance for thermal expansion

On long continuous rail runs, expansion can bend the rail, snap the L-brackets or pull the fixings out. Always allow for sufficient expansion gaps on long continuous rail runs.

See: Rails and componentsL-bracket full rail installation manual

Clamping panels outside the panel manufacturer's clamping zones

Clamps outside the correct clamping zones put stress on the weaker parts of the panel. Module manuals are clear that deviating from the installation manual invalidates the warranty.

See: Rails and componentsFlush mount installation manual

Ground mounts

No soil check before choosing the foundation

Skipping a geotechnical analysis can leave the array unstable when the soil doesn't suit the foundation.

See: Ground mount foundationsGround mount spec sheets

Uneven ground that isn't graded first

It creates uneven loads on the mounting structure, which leads to long-term stress and possible failure.

See: Ground mount kitGround mount spec sheets

Loose assembly

Loose bolts and misaligned rails place unnecessary stress on the panels.

See: Ground mount kitGround mount spec sheets

Both roof and ground

Wrong torque

One of the most common errors with any mounting structure is over-torquing fasteners, which stresses the fasteners and module frames. Under-torquing causes the loosening problems above. Use a torque wrench and the torque in the manual.

See: Manuals and documents

The bottom line

Almost every issue above is covered in the installation manual. Many problems can be avoided by following the manufacturer's instructions, and that includes the mounting structure. Read the manual for both the structure and the panels before starting any installation.

See: Manuals and documents

Questions

Why do mounting structures fail?

Most structure failures we hear about aren't product failures. They're installation shortcuts. The same handful of mistakes come up again and again, on roofs and on ground mounts.

How should a tile hook sit?

A correctly installed hook sits between two courses of tiles without putting pressure on the tile below. If it does bear on the tile, years of gusts flex the hooks and crack the tiles they rest on.

What torque should fasteners be tightened to?

Over-torquing fasteners stresses the fasteners and module frames, and under-torquing causes loosening. Use a torque wrench and the torque in the manual.

How can most installation problems be avoided?

Almost every issue is covered in the installation manual. Read the manual for both the structure and the panels before starting any installation.