What is in each system
A mini rail system has three parts on the roof: the mini rail, the inter clamp and the end clamp. A full rail system adds the roof cleat or clamp, the rail, rail nuts and splices.
Explore in 3D: PRO Rail H and its partsPRO Rail H and its parts
Explore in 3D: PRO Rail 47 and its partsPRO Rail 47 and its parts
Explore in 3D: Full rail on IBR cleatsFull rail on IBR cleats
| Item | Mini rail | Full rail |
|---|---|---|
| Parts on the roof | Mini rail, inter clamp, end clamp | Roof cleat or clamp, rail, rail nut, splice, inter clamp, end clamp |
| Rail | None: the clamps fix to the mini rail | PRO Rail H (flush mount) or PRO Rail 47 (flush, tilt and tile) |
| Roofs | IBR, corrugated, Saflok 410 and 700 | IBR, Klip-Lok / Saflok, corrugated on L-brackets, hanger bolts, Novotexi |
| Earthing | Through the clamps, with earthing plates in the inter clamps | Earthing plates in the inter clamps; one grounding lug per rail row |
| Option | Choose this if |
|---|---|
| Mini rail | Portrait or landscape modules on IBR, corrugated or Saflok sheeting, with nothing to clear: the clamps go straight onto the roof interface, with fewer parts. |
| Full rail | Portrait or landscape modules on sheeting, an array that must clear obstructions or flashings, tile hooks, tilt legs, or where more airflow is required under the panels. |
Our mini rail kits
All are anodised aluminium, each for one roof: two for IBR (standard and longer), one for corrugated, and a Saflok clamp kit for 410 and 700 that grips the rib with no penetration, plus a Saflok tilt version. They are fixed in a straight line and the modules clamped straight onto them.
On Klip-Lok, the 2 MWp hybrid rooftop with battery storage in Gauteng runs across several pitched roof sections on Saflok 410/700 mini-rail clamp kits (LMS-KL1-MR-KIT), clamped to the roof seams with no roof penetration. Short mini rails in place of full-length rail cut the material on the roof and speed up installation.
When the layout needs full rail
- Portrait or landscape modules on sheeting where mini rails are not possible: hanger bolt and L-bracket full rail.
- More airflow: the Klip-Lok full-rail solution.
- Obstructions: on a new home in KwaZulu-Natal, 10° tripod kits on L-bracket full rail clear skylights and other openings.
- Roof flashings: Highveld Mall in eMalahleni (2,469 kWp) runs full rail across them.
- Corrugated L-brackets, tile hooks and tilt legs carry PRO Rail 47; the one tilt mini rail is the Saflok 410/700 mini-rail clamp tilt support kit.
Rules for full rail
- Always two rails under each row of modules, portrait or landscape.
- Each rail sits on multiple roof clamps, as determined by our spacing calculator.
- Splices and overhangs follow the installation manual on the flush mount page.
- How far a rail runs past the end module depends on the rail lengths and panel widths.
From the field
Always allow for sufficient expansion gaps on long continuous rail runs. Clamps outside the correct clamping zones put stress on the weaker parts of the panel.
Earthing, rail or no rail
On full rail, earthing plates in the inter clamps bond rail and module, so every panel in a row is electrically bonded, with one grounding lug per rail row. Earthing plates are single use. On mini rails the modules bond through the clamps, with earthing plates in the inter clamps.
What to order
- Order the roof clamp or mini rail kit that grips your sheet's rib, one per fixing: IBR, LMS-MRAIL-PRO-KIT (or the longer LMS-MRAIL-PRO-EXT-KIT); Klip-Lok / Saflok, LMS-KL1-MR-KIT; corrugated, LMS-COR-MR-KIT. Inclined on Saflok: LMS-KL2-MR-TILT-KIT.
- Full-rail interfaces: LMS-IBR1-KIT-PRO and LMS-IBR2-KIT-PRO (IBR cleats), LMS-KL1-KIT (Saflok 410/700 cleat), LMS-LB-COR-KIT-P and LMS-LB-COR-KIT-L (corrugated L-brackets).
- Rails: PRO Rail 47 (LMS-PRO-RAIL47) in 3150, 4150, 4400, 4700 and 5150 mm; PRO Rail H (LMS-PRO-RAILH) in 3150, 4150, 4700 and 5150 mm.
- Clamps: LMS-EC30-35-KIT (end) and LMS-IC30-35-KIT (inter); each kit is one clamp with its bolt and rail nut. Grounding lug: LMS-EGL-KIT, one per rail row.
- Rail nuts: included in the L-bracket and tile hook kits; for IBR cleats, one rail nut kit per fixing.
Send the layout, module size and orientation, and our bill of materials gives the rail lengths, clamp counts and interface quantities. The rails and components page lists every part.
Questions
Does a mini rail need a full rail as well?
No. The end and inter clamps fix straight onto the mini rails.
Which roofs take Lumasol mini rails?
IBR, corrugated, and Saflok 410 and 700, with a non-penetrative tilt version for Saflok.
When is full rail used instead?
Where the array must clear obstructions or flashings, where more airflow is required under the panels, under tile hooks and tilt legs, and on sheeting where mini rails are not possible, portrait or landscape.
How are the modules earthed on mini rails?
Through the clamps, with earthing plates in the inter clamps between modules; the installation manual shows the method.
Which rail lengths are available?
PRO Rail 47 in 3150, 4150, 4400, 4700 and 5150 mm, and PRO Rail H in 3150, 4150, 4700 and 5150 mm.