Skip to content

Tile and slate roof solar hooks

Stainless steel hooks that carry the rail clear of concrete tile, clay tile and slate roofs.

Show the kit as
Representative model of the tile and slate kit (Portrait hook), assembledRepresentative modelView in 3D
Portrait hookLMS-TH1-KIT
Hook, screwed to rafterRail, cut

Tile hook in section along the slope: fixed to the rafter, it passes under the tile above and carries the rail.

Anodised as standard
10 µm
Every aluminium part is AL6005-T5, anodised to 10 µm as standard, not mill finish. Hooks and fasteners are SUS304 stainless steel.
Roof pitch
0° to 30°
Outside this range, a project-specific certificate
Hook spacing
1.5 m
Roof up to 10 m, roof tilt up to 25°, roof zone H
Adjustable hook
56 to 83 mm
Height range of LMS-TH4-KIT
Warranty
Up to 20 years
SUS304 hooks and aluminium parts, C1 to C4

What is in the kit

Choose the hook. The model and the hook code change with it. Select any part for its material and finish.

Hook
Representative model of the tile and slate kit on Concrete or clay tile, assembled
Drag to rotate, select a part for its code
Representative model

Keyboard: select the model, then arrow keys rotate, + and − zoom, 1 to 4 choose a view, E separates the parts.

Parts in the kit, with catalogue codes. Select a part to show it in the model.
ItemDescriptionCode
1LMS-EC30-35-KIT, LMS-IC30-35-KIT
2LMS-PRO-RAIL47
3LMS-TH1-KIT
4Earth grounding lug, one per rail row; earthing cable bolt M8 × 20Not shown in the model or the drawingLMS-EGL-KIT

Select a part, in the list or in the model, for its code, material and finish.

A representative model for reading the assembly, not a design drawing. PV modules are shown for reference and are not part of the kit. Quantities are set for each project.

Plan your project

Choose the roof or site, add the pitch and the town, and send your layout for a firm quote.

What are you mounting on?

Where it fits

For residential and commercial tile roofs in concrete tile, clay tile or slate. The hook is fixed to the rafter and carries the rail without bearing on the tiles.

  • Concrete or clay tile, portrait rows

    Tile hook kit, portrait (LMS-TH1-KIT), L180 × 166 × 155, SUS304 or 410; hot-dip galvanised as LMS-TH3-KIT.

  • Concrete or clay tile, landscape rows

    Tile hook kit, landscape (LMS-TH2-KIT), L180 × 166 × 155, SUS304.

  • Uneven batten spacing

    Adjustable tile hook kit (LMS-TH4-KIT), height 56 to 83 mm, SUS304.

  • Slate

    Slate hook kit (LMS-SH1-KIT), SUS304.

Configurations

Three hooks for concrete and clay tile roofs, all from the tile manual.

On site

Tile and slate roofs carrying solar, commercial and residential: clay tile and slate.

  • A run of solar modules two across on a grey slate roof, rail ends and clamps at the lower edge, pine trees alongside
  • A commercial building from the air: arrays on its clay tile roofs and the flat roofs beside them, parking in front
  • A commercial block from the air: arrays on several clay tile roof planes and neighbouring flat roofs, at a road junction
  • Rows of modules on the clay tile and flat roofs of a commercial building, under an overcast sky, a church spire behind
  • Two small solar arrays on either side of the hip of a house's clay tile roof, with trees and neighbouring houses behind

Specification

From the Lumasol installation manual and product catalogue. Each system is designed for its project and ships with a detailed installation guide.

Compare tile and slate with the other kit families
Tile and slate specification
MaterialsSUS304 stainless steel tile and slate hooks. AL6005-T5 PRO Rail 47 and clamps.
FinishAluminium anodised to 10 µm.
Design basisWind regions A to D, up to 20 m installation height.Designed for terrain category C, with spacing factors for A and B.
Roof pitch0° to 30°; outside this range, a project-specific engineering certificate.Full 1.5 m spacing up to 25° roof tilt.
OrientationPortrait (LMS-TH1-KIT) or landscape (LMS-TH2-KIT) hooks.
Corrosion classAnodised aluminium and SUS304 stainless steel: 20 years in C1 to C3 and in C4, not warranted in C5. Screws (1022A, class 3): 20 years in C1 to C3.Reduce interface spacing by 5% in C4.
Interface spacingUp to 1.5 m.Roof height to 10 m, roof tilt to 25° and the array in roof zone H. Hook spacing follows the truss spacing.
Modules30 mm and 35 mm frames, at least 18 mm between modules.
FasteningHooks into the rafters with timber screws, minimum 25 mm embedment. Rail to hook and clamps 16 to 20 N·m.The hook must not bear on the tile; raise it with a timber block if needed.

Materials and corrosion by site

Materials and corrosion by site

  • Tile and slate hooks: SUS304 stainless steel.
  • PRO Rail 47 and clamps: AL6005-T5 aluminium, anodised to 10 µm.
  • Splice star washers pierce the anodising to bond the rails; the earthing plates in the inter clamps bond the module frames.
  • Tiles, battens, timber screws and PV modules are not in the Lumasol component list.
Warranty and interface spacing by ISO 9223 corrosion class
Site classSUS304 hooks and fixingsAluminium rail and clampsGalvanised steel partsInterface spacing
C1 to C3Inland20 years20 years20 yearsAs designed, up to 1.5 m
C4Coastal or industrial20 years20 yearsNot warrantedReduce by 5%
C5SevereNot warrantedNot warrantedNot warrantedNot applicable
  • Classes to ISO 9223. The warranty period runs from the date of delivery. It applies once the original purchaser registers it within 30 days of purchase.
  • Where a site's class is uncertain, treat it as the higher class and confirm it with Lumasol.

Spacing and design basis

Spacing and design basis

The conditions the tile manual sets for the full 1.5 m hook spacing.

Interface spacing conditions by configuration
ConditionPortrait, landscape and adjustable hooks
Maximum hook spacing1.5 m, following the truss spacing
Roof heightUp to 10 m
Roof tiltUp to 25°
Roof zoneZone H
Terrain categoryDesigned for C. Factors for A (90%) and B (95%)
C4 siteReduce spacing by 5%
Rail end overhangUp to 40% of the last span
Gap between modulesAt least 18 mm down the slope
  • Roof slopes 0° to 30° and installation heights up to 20 m; outside these, a project-specific engineering certificate is needed.
  • Outside these limits, reduce the spacing and confirm it with Lumasol before installing.
  • Rails must sit within the module's clamping zones; take them from the module manufacturer's manual.

Installation

Installation

The sequence from the Lumasol manual, for the portrait hook. The manual is the reference on site.

  1. Step 1: Plan the layout

    • Confirm the wind region, terrain category, ISO 9223 class, roof height and slope (0° to 30°).
    • Allow at least 18 mm between modules down the slope.
    • Set the horizontal hook spacing by the rafter spacing, no more than 1500 mm; set the rail spacing inside the module's clamping zones.
  2. Step 2: Fix the hooks

    • Remove the tiles at the marked positions, or push them up slightly.
    • Fix each hook to the rafter with timber screws, at least 25 mm embedment: 3/8" hex socket, no more than 3,000 RPM.
    • The hook must not press on the tile: raise it with a timber block if needed, and grind a recess in the tile above so it lies flat.
    • Set the hooks out in a straight line. Never use a fitted hook as a step.
  3. Step 3: Fit the rails

    • Fix the rail to the hooks at 16 to 20 N·m once it is in position. With the height extender, fix hook and extender first, then the rail, both at 16 to 20 N·m.
    • Join rails with the splice within ¼ span of a support, never over a support or at mid-span, at 16 to 20 N·m.
    • Each rail sits on multiple tile hooks, as determined by our spacing calculator.
  4. Step 4: Clamp the modules

    • Fix the first module with an end clamp, lightly. Lift it slightly, slide in inter clamps with earthing plates, then place the next module.
    • The end clamp comes pre-set for 30 mm frames; for 35 mm, put the bolt in the second hole, turned 90°.
    • Earthing plates are single use. Tighten every clamp to 16 to 20 N·m once the modules are in their final position.
Torques
FixingCodesTorque
End and inter clampsLMS-EC30-35-KIT, LMS-IC30-35-KIT16 to 20 N·m
Rail to hookLMS-TH1-KIT, LMS-TH2-KIT, LMS-TH4-KIT16 to 20 N·m
Rail joinerLMS-PRO-RAIL47-SP-KIT16 to 20 N·m
Grounding lugLMS-EGL-KIT16 to 20 N·m
Adjustable hook height boltLMS-TH4-KIT33 to 40 N·m

Stainless fasteners can gall. Apply force evenly along the thread, use power tools at low speed, and avoid impact drivers.

Tools

  • Allen keys
  • Nut setter or screwdriver
  • Tape measure
  • Chalk line or string
  • Spirit level
  • Marker pen
  • Torque spanner
  • Angle grinder

Tile and slate or flush mount

The nearest kit in the range, side by side, from the two manuals.

Flush mount specifications
Tile and slate compared with flush mount
FeatureTile and slateFlush mount
RoofConcrete tile, clay tile and slateMetal sheeting: IBR, Klip-Lok / Saflok, corrugated and more
FixingHooks screwed to the rafters, clear of the tilesCleats or clamps on the sheet ribs, or L-brackets
Full 1.5 m spacingRoof height up to 10 m, roof tilt up to 25°, roof zone HRoof height up to 20 m, roof tilt up to 18° or 10°
RailPRO Rail 47PRO Rail H, or Rail 47 on L-brackets
Gap between modulesAt least 18 mmAt least 18 mm

Technical questions

Does the hook rest on the tile?

No. The hook is fixed to the rafter with timber screws and must not press against the roof tile. If it is not high enough, raise it with a wooden block. Where needed, grind a recess in the tile that sits over the hook so the tile lies flat.

How are the hooks fixed?

Into the rafters with timber screws at a minimum 25 mm embedment, using a 3/8" hex socket at no more than 3,000 RPM. Never use fitted hooks as a step.

Which hook do I need?

Portrait rows use LMS-TH1-KIT and landscape rows LMS-TH2-KIT. The adjustable hook LMS-TH4-KIT adjusts in height from 56 mm to 83 mm, with the height bolt tightened to 33 to 40 N·m. A slate hook, LMS-SH1-KIT, is listed in the catalogue.

When can hooks be spaced at 1.5 m?

Roof height up to 10 m, roof tilt up to 25° and the array in roof zone H. Horizontal hook spacing follows the truss spacing and should not exceed 1500 mm. Outside these limits, reduce the spacing.

What roof pitch is covered?

Roof slopes from 0° to 30°. Outside this range a project-specific engineering certificate is required.

What about coastal sites?

SUS304 hooks and fasteners are warranted for 20 years in C1 to C4 and are not warranted in C5. In C4, reduce the interface spacing by 5%. Galvanised steel parts are warranted only in C1 to C3.

Quote a tile and slate kit