Flush mount vs tilt mount: 5°, 10° and 20°

Flush mount fixes the panels parallel to the roof, at the roof's own pitch; tilt mount adds front and rear legs that set the panels at 5°, 10° or 20° where the roof gives too little angle, such as flat concrete roofs and low-pitch sheeting.

For its 10° projects, Lumasol gives three reasons for the incline: more yield than panels lying flat, rain washing the panels, and a lower wind load than a steeper tilt.

Last updated . Reviewed by the Lumasol technical team.

Key points

  • Flush mount: panels parallel to a metal-sheet roof, at its own pitch.
  • Tilt mount: legs set the panels at 5°, 10° or 20° on flat and low-pitch roofs, metal or concrete.
  • Only the rear leg changes between the three angles.
  • Steeper tilts need closer roof fixings; we set the spacing per site.
  • Both come penetrative or non-penetrative.
Lumasol 10 & 20 Degree Incline System for Mounting Solar Panels onto IBR Roof Sheeting.The video loads from YouTube, which sets its own cookies.

Flush mount: the roof's own pitch

A flush mount kit fixes the panels parallel to a metal-sheet roof, at slopes from 0° to 30°, on PRO Rail H (PRO Rail 47 on corrugated L-brackets) or, on some roofs, mini rails.

Most of the largest rooftops on Lumasol structure are flush mount, among them Truda Foods (2,840 kWp) and a 1.75 MWp commercial rooftop.

Tilt mount: 5°, 10° or 20°

A tilt kit adds a front leg and a rear leg made for 5°, 10° or 20°, carrying PRO Rail 47. It suits flat and low-pitch metal roofs and concrete flat roofs, penetrative or non-penetrative.

On our 10° projects the incline gives more yield than panels lying flat, lets rain wash the panels, and keeps the wind load below that of a steeper tilt. Toyota and Kombat are on 10° kits on IBR; Village Baker in Eswatini (215.6 kWp) is on 20°.

The two families compared

The same roof, flush and at 10°.
Flush mount and tilt mount, from the Lumasol manuals and kit pages
ItemFlush mountTilt mount
Panel angleThe roof's own pitch5°, 10° or 20° above the roof
RoofsIBR, Klip-Lok / Saflok, corrugated, standing seam, Novotexi 440Flat and low-pitch metal roofs, concrete flat roofs
RailPRO Rail H, Rail 47 on L-brackets, or mini railsPRO Rail 47
Roof slopes covered0° to 30°0° to 30°
Wind designRegions A to D, up to 20 m installation heightRegions A to D, up to 20 m installation height
Fixing spacingSet per siteCloser at 10° and 20°; set per site
Which to choose
OptionChoose this if
Flush mountThe roof is metal sheeting with enough pitch of its own, and you want the panels flat to the roof on the simplest kit.
Tilt mountThe roof is flat or low pitch, metal or concrete, and you want the extra yield, rain washing and lower wind load a 10° incline gives on our projects.

Choosing 5°, 10° or 20°

Representative models. One front leg; the rear leg sets the angle.

All three angles use the same front leg; only the rear leg changes. The angle also sets the spacing between roof fixings: a 5° kit on a flat roof keeps the widest spacing, while 10° and 20° kits go in closer, which we set for each site with our spacing calculator.

Send the roof height, slope and wind region with the quote. The figures are in the installation manuals on the tilt mount page.

Other ways to incline panels

  • Cardwell bracket inclined system: brackets bridge two IBR ridges, so panels on a south-facing slope face north at 10°, without long rail across the span.
  • Tripod kits, 10° and landscape: two per panel, on L-bracket full rail, for roofs with obstructions.
  • E/W ballast and inclined weighted ballast: for concrete flat roofs, with no roof penetration.

Each is on the tilt mount page.

Introducing the Lumasol Inclined Weighted Ballast Mounting SystemThe video loads from YouTube, which sets its own cookies.

Penetrative or non-penetrative

Both families come both ways: a tilt base screwed into the purlins, or a non-penetrative kit on the Saflok 410/700 cleat, Saflok 410/700 mini-rail clamp tilt support kit or standing seam clamp. The penetrative vs non-penetrative guide compares the fixings.

What to order

  • Legs: LMS-FL-KIT-PRO (front), with LMS-ARL5-KIT-PRO, LMS-ARL10-KIT-PRO or LMS-ARL20-KIT-PRO (rear, for 5°, 10° or 20°).
  • IBR: LMS-IBR3-KIT-PRO (side-fix tilt support).
  • Corrugated: the tilt kits above, mounted onto LMS-LB-COR-KIT-P or LMS-LB-COR-KIT-L (corrugated L-brackets) with a full rail system.
  • Saflok, non-penetrative: LMS-KL2-MR-TILT-KIT.
  • Cardwell brackets: LMS-CB-300-KIT.
  • Not in the kit: anchors for concrete roofs and earthing cable, bought separately.

Questions

Is there a non-penetrative tilt option?

Yes: the Saflok 410/700 cleat, the Saflok 410/700 mini-rail clamp tilt support kit or the standing seam clamp kit. The clamp is accredited on Saflok 700 and 410; for other sheets we recommend an on-site pull-out test.

Which tilt angles does Lumasol make?

5°, 10° and 20°: one front leg kit, with a rear leg kit for each angle.

Why incline panels at 10° on a roof?

On our 10° projects the panels give more yield than lying flat, rain washes them, and the wind load stays lower than at a steeper tilt.

Does a steeper tilt change the fixing spacing?

Yes. 10° and 20° kits go in at closer spacing than a 5° kit on a flat roof, which we set for each site with our spacing calculator.

Can tilt legs go on a flat concrete roof?

Yes, fixed with chemical anchors or expansion bolts to the anchor's datasheet. Where the roof cannot be penetrated, weighted ballast holds the array instead.

Can panels on a south-facing IBR slope face north?

Yes, with the Cardwell bracket inclined system: the brackets bridge two IBR ridges and incline the panels 10° to the north, without long rail across the span.