Tilt mount solar kits

Front and rear leg kits that set solar panels at 5°, 10° or 20° on flat and low-pitch roofs.

Show the kit as
Representative model of the tilt mount kit (5°), assembledRepresentative modelView in 3D
5°LMS-ARL5-KIT-PRO
10°Rear legFront leg

Tilt mount: front and rear legs set the rail and module at 5°, 10° or 20° above the roof.

Anodised as standard
10 µm
Every aluminium part is AL6005-T5, anodised to 10 µm as standard, not mill finish. Fasteners are SUS304 stainless steel.
Panel tilt
5°, 10°, 20°
Rear leg kits LMS-ARL5-KIT-PRO, LMS-ARL10-KIT-PRO and LMS-ARL20-KIT-PRO
Roof pitch
0° to 30°
Roof slopes the tilt manuals cover
Interface spacing
1.5 m
Where roof tilt plus panel tilt is 5° or less, wind region A or B
Warranty
Up to 20 years
Aluminium and SUS304 parts, C1 to C4

What is in the kit

Choose the tilt angle. The model and the rear leg kit change with it. Select any part for its material and finish.

Tilt angle
Representative model of the tilt mount kit on IBR, corrugated sheeting or wooden or metal purlins, assembled
Drag to rotate, select a part for its code
Representative model

Keyboard: select the model, then arrow keys rotate, + and − zoom, 1 to 4 choose a view, E separates the parts.

Parts in the kit, with catalogue codes. Select a part to show it in the model.
ItemDescriptionCode
1LMS-EC30-35-KIT
2LMS-IC30-35-KIT
3LMS-PRO-RAIL47
4LMS-ARL5-KIT-PRO
5LMS-FL-KIT-PRO
6LMS-PRO-RAIL47-SP-KIT

Select a part, in the list or in the model, for its code, material and finish.

A representative model for reading the assembly, not a design drawing. PV modules are shown for reference and are not part of the kit. Quantities are set for each project.

Plan your project

Choose the roof or site, add the pitch and the town, and send your layout for a firm quote.

What are you mounting on?

Where it fits

For flat and low-pitch metal roofs and concrete flat roofs, where the panels need more angle than the roof gives. Penetrative and non-penetrative fixings.

  • IBR

    IBR side-fix tilt support kit (LMS-IBR3-KIT-PRO, L100) with EPDM seal.

  • Corrugated

    Tilt kits (front leg LMS-FL-KIT-PRO and rear leg LMS-ARL5-KIT-PRO, LMS-ARL10-KIT-PRO or LMS-ARL20-KIT-PRO) mounted onto corrugated L-bracket kits (LMS-LB-COR-KIT-P or LMS-LB-COR-KIT-L) with a full rail system. Not the IBR side-fix tilt support, which is only for IBR roof sheets.

  • Klip-Lok / Saflok 410 and 700

    Saflok 410/700 cleat (LMS-KL1-KIT) or Saflok 410/700 mini-rail clamp tilt support kit (LMS-KL2-MR-TILT-KIT). No roof penetration.

  • Concrete flat roofs

    Commercial tilt kits (LMS-COBE-FL-10-KIT, LMS-COBE-RL-10-KIT, LMS-COBE-EW-KIT), fixed with chemical anchors or expansion bolts.

  • Wooden and metal purlins

    Hanger bolt and L-bracket kit for wooden purlins (LMS-HB-LB-KIT) or metal purlins (LMS-HB-LB-KIT-M).

  • Novotexi 440

    Novotexi 440 cleat (LMS-NVT-KIT). No roof penetration.

Configurations

Three tilt angles, set by the rear leg kit on the same front leg, rail and clamps.

Side elevations of the tilt kit at 5°, 10° and 20°
5°LMS-ARL5-KIT-PRO10°LMS-ARL10-KIT-PRO20°LMS-ARL20-KIT-PRO
  • Front and rear legs at 5°

    Roof
    IBR, corrugated sheeting or wooden or metal purlins
    Fixing
    Penetrative: bases screwed to the purlins
    Interface
    Rear leg kit, 5°LMS-ARL5-KIT-PRO
    Rail
    PRO Rail 47
    Full spacing
    1.5 m only where roof tilt plus panel tilt is 5° or less: on a flat roof

    With the front leg kit LMS-FL-KIT-PRO. The same legs go on Klip-Lok / Saflok rib clamps (non-penetrative), on corrugated L-bracket kits (LMS-LB-COR-KIT-P or LMS-LB-COR-KIT-L) with a full rail system and, with chemical anchors or expansion bolts, on concrete flat roofs.

  • Front and rear legs at 10°

    Roof
    IBR, corrugated sheeting or wooden or metal purlins
    Fixing
    Penetrative: bases screwed to the purlins
    Interface
    Rear leg kit, 10°LMS-ARL10-KIT-PRO
    Rail
    PRO Rail 47
    Full spacing
    At 10° the roof tilt plus panel tilt is over 5°, so the spacing is reduced: confirm it with Lumasol

    With the front leg kit LMS-FL-KIT-PRO. The same legs go on Klip-Lok / Saflok rib clamps (non-penetrative), on corrugated L-bracket kits (LMS-LB-COR-KIT-P or LMS-LB-COR-KIT-L) with a full rail system and, with chemical anchors or expansion bolts, on concrete flat roofs.

  • Front and rear legs at 20°

    Roof
    IBR, corrugated sheeting or wooden or metal purlins
    Fixing
    Penetrative: bases screwed to the purlins
    Interface
    Rear leg kit, 20°LMS-ARL20-KIT-PRO
    Rail
    PRO Rail 47
    Full spacing
    At 20° the roof tilt plus panel tilt is over 5°, so the spacing is reduced: confirm it with Lumasol

    With the front leg kit LMS-FL-KIT-PRO. The same legs go on Klip-Lok / Saflok rib clamps (non-penetrative), on corrugated L-bracket kits (LMS-LB-COR-KIT-P or LMS-LB-COR-KIT-L) with a full rail system and, with chemical anchors or expansion bolts, on concrete flat roofs.

More in this family

  • E/W ballast system

    For concrete flat roofs: east-west ballasted arrays with no roof penetration. See Weighted ballast, below.

  • Inclined weighted ballast

    For concrete flat roofs: the array is held by weighted ballast, without penetrating the roof surface. See Weighted ballast, below.

    Introducing the Lumasol Inclined Weighted Ballast Mounting SystemThe video loads from YouTube, which sets its own cookies.
  • Cardwell bracket inclined system

    Universal Cardwell brackets bridge two IBR ridges, so panels on a south-facing slope can be inclined 10° to the north without full-length rail across the span.

    • Inclined solar panel rows on an IBR roof
    • A tripod kit bracket under a module
    • Installers placing a module on the incline kits
  • Tripod kits, 10° and landscape

    Two per panel, in landscape at a 10° incline, used with L-bracket full rail on roofs with obstructions.

Weighted ballast

For flat roofs where a penetration is not an option, in east-west and inclined versions. East-west carries a lower wind load, so it needs fewer and lighter blocks.

  • Each structure is mechanically bolted to individual concrete blocks, two bolts per block.
  • The blocks sit on anti-wear EPDM mats, which protect the roof membrane and keep drainage open.
  • The ballast mass for each panel is set from site-specific wind simulations by Lumasol's engineers.
  • The blocks are reinforced and have provision for integrated wind-safety gust lines.
  • Rows of concrete ballast blocks on a flat roof
  • A structure bolted to its concrete ballast blocks
  • Inclined ballast frames on a coated flat roof

Specification

From the Lumasol installation manual and product catalogue. Each system is designed for its project and ships with a detailed installation guide.

Compare tilt mount with the other kit families
Tilt mount specification
MaterialsAL6005-T5 aluminium legs, PRO Rail 47, splices and supports. SUS304 stainless hardware.
FinishAluminium anodised to 10 µm. Splice star washers bond the rails.
Design basisWind regions A to D (32 to 44 m/s, 50-year recurrence, SANS 10160-3). Assessed for terrain categories C and D, up to 20 m installation height.Non-penetrative system calculated to SANS 10160-3:2019 for roof zone A.
Roof pitch and tiltRoof slopes 0° to 30°. Rear leg kits set the panels at 5°, 10° or 20°.
Corrosion classAnodised aluminium and SUS304 stainless steel: 20 years in C1 to C3 and in C4, not warranted in C5. Screws (1022A, class 3): 20 years in C1 to C3.Reduce interface spacing by 5% in C4 and 25% in C5.
Interface spacingUp to 1.5 m.Roof height to 15 m, roof tilt plus panel tilt to 5°, roof zone A, terrain category D, wind region A or B, clamp pull-out at least 3.5 kN. Otherwise reduced.
Modules30 mm and 35 mm frames, at least 20 mm between modules.
FasteningLegs, splices, clamps and rail nuts 16 to 20 N·m.Penetrative bases screw into metal or timber purlins 0.42 to 2.4 mm thick over EPDM. Concrete roofs: chemical anchors or expansion bolts to the anchor datasheet.

Materials and corrosion by site

Materials and corrosion by site

  • Front and rear legs, PRO Rail 47, splices and supports: AL6005-T5 aluminium, anodised to 10 µm.
  • Bolts and splice hardware: SUS304 stainless steel.
  • Penetrative bases sit on EPDM rubber and screw to the purlins with waterproof washers.
  • Splice star washers pierce the anodising to bond the rails; the earthing plates in the inter clamps bond the module frames.
  • Anchors for concrete roofs and earthing cable are not in the Lumasol component list.
Warranty and interface spacing by ISO 9223 corrosion class
Site classAluminium and SUS304 partsScrews (1022A, class 3)EPDM and other non-metallic partsInterface spacing
C1 to C3Inland20 years20 years3 yearsAs designed, up to 1.5 m
C4Coastal or industrial20 yearsNot warranted3 yearsReduce by 5%
C5SevereNot warrantedNot warranted3 yearsReduce by 25% (both tilt manuals)
  • Classes to ISO 9223. The warranty period runs from the date of delivery. It applies once the original purchaser registers it within 30 days of purchase.
  • Where a site's class is uncertain, treat it as the higher class and confirm it with Lumasol.

Spacing and design basis

Spacing and design basis

The conditions both tilt manuals set for the full 1.5 m interface spacing. They are the same for both fixings.

Interface spacing conditions by configuration
ConditionPenetrative (bases on purlins)Non-penetrative (Saflok / Klip-Lok)
Maximum interface spacing1.5 m1.5 m
Roof heightUp to 15 mUp to 15 m
Roof tilt plus panel tiltUp to 5°Up to 5°
Roof zoneZone AZone A
Terrain categoryDD
Wind regionA or B (up to 36 m/s)A or B (up to 36 m/s, SANS 10160-3)
Clamp pull-outAt least 3.5 kNAt least 3.5 kN, on accredited sheets
C4 siteReduce spacing by 5%Reduce spacing by 5%
C5 siteReduce spacing by 25%Reduce spacing by 25%
Rail end overhangUp to 40% of the last spanUp to 40% of the last span
  • Both systems suit roof slopes from 0° to 30°, with guidance up to 20 m installation height; above 20 m a project-specific engineering certificate is needed.
  • Any installation outside these limits needs reduced spacing. Confirm it with Lumasol before installing.
  • The non-penetrative clamp is accredited on Saflok 700 and Saflok 410; on any other sheet, test pull-out on site.

Installation

Installation

The sequence from the Lumasol manual, for the 5° rear legs. The manual is the reference on site.

  1. Step 1: Plan the layout

    • Confirm the wind region, terrain category, ISO 9223 class, roof height and slope (0° to 30°).
    • Allow at least 20 mm between modules for the inter clamps; set the brackets about ½ to ¾ of the module height apart.
    • Take the clamping zone from the module manufacturer's manual, allowing for the design angle and the purlin spacing.
  2. Step 2: Fix the bases

    • Screw each tilt base to the metal or wooden purlin beneath the sheeting: through the holes on both sides, or through the centre hole with EPDM rubber under the base.
    • Self-tapping screws with waterproof washers: 3/8" hex socket, no more than 300 RPM, square to the surface, neither over- nor under-tightened. Purlins 0.42 to 2.4 mm thick.
    • Set the bases out in a straight line. On a concrete flat roof, use chemical anchors or expansion bolts to their own datasheet.
  3. Step 3: Fit the legs

    • Position and align the front and rear legs in the direction the installation plan shows.
    • Leave the fasteners loose until the angle is set, then tighten to 16 to 20 N·m.
  4. Step 4: Fit the rails

    • Fix the rails to the legs with the rail nut kits at 16 to 20 N·m, the rail grooves meshing with the leg grooves.
    • Join rails with the splice within ¼ span of a support, never over a support or at mid-span, at 16 to 20 N·m. The star washers bond the rails.
    • Every rail sits on multiple supports, as determined by our spacing calculator.
  5. Step 5: Clamp the modules

    • Fix the first module with an end clamp, lightly. Lift it slightly, slide in inter clamps with earthing plates, then place the next module.
    • The end clamp comes pre-set for 30 mm frames; for 35 mm, put the bolt in the second hole, turned 90°.
    • Earthing plates are single use. Tighten every clamp to 16 to 20 N·m once the modules are in their final position.
Torques
FixingCodesTorque
End and inter clampsLMS-EC30-35-KIT, LMS-IC30-35-KIT16 to 20 N·m
Rail spliceLMS-PRO-RAIL47-SP-KIT16 to 20 N·m
Tilt splice kitLMS-TILT-SPLICE-KIT16 to 20 N·m
Front and rear leg kitsLMS-FL-KIT-PRO, LMS-ARL5-KIT-PRO, LMS-ARL10-KIT-PRO, LMS-ARL20-KIT-PRO16 to 20 N·m
Rail to legs, rail nut kitsLMS-RN-M8x20-KIT16 to 20 N·m

Stainless fasteners can gall. Apply force evenly along the thread, use power tools at low speed, and avoid impact drivers.

Tools

  • Screwdriver
  • Drill bits for M8 bolts
  • Torque spanner
  • 5 m tape
  • Marker pen
  • String line
Lumasol 10 & 20 Degree Incline System for Mounting Solar Panels onto IBR Roof Sheeting.The video loads from YouTube, which sets its own cookies.
Download Tilt mount, penetrative: installation manualPDF, 3.2 MB

Tilt mount or flush mount

The nearest kit in the range, side by side, from the two manuals.

Flush mount specifications
Tilt mount compared with flush mount
FeatureTilt mountFlush mount
Panel angle5°, 10° or 20° above the roof, set by the rear leg kitParallel to the roof
RoofsIBR, corrugated (on corrugated L-bracket kits with full rail), Klip-Lok / Saflok, concrete flat roofs, wooden or metal purlins, Novotexi 440IBR, Klip-Lok / Saflok, corrugated, standing seam, Novotexi 440
Full 1.5 m spacingRoof tilt plus panel tilt up to 5°, wind region A or BRoof tilt up to 18° (penetrative) or 10° (non-penetrative)
Roof height for full spacingUp to 15 mUp to 20 m
Clamp pull-out for full spacingAt least 3.5 kNAt least 2.5 kN
RailPRO Rail 47PRO Rail H, or Rail 47 on L-brackets
Choose it whenThe roof is flat or low-pitch and the panels need more angle than it givesThe roof's own pitch and direction suit the array

Technical questions

Which tilt angles are available?

Rear leg kits are made for 5°, 10° and 20° (LMS-ARL5-KIT-PRO, LMS-ARL10-KIT-PRO, LMS-ARL20-KIT-PRO), used with the front leg kit LMS-FL-KIT-PRO.

What roof slopes do the tilt kits suit?

Roof slopes from 0° to 30°. The full 1.5 m interface spacing applies only where roof tilt plus panel tilt is 5° or less.

When can tilt kits be spaced at 1.5 m?

Roof height up to 15 m, roof tilt plus panel tilt up to 5°, roof zone A, terrain category D, roof clamp pull-out of at least 3.5 kN, and wind region A or B (up to 36 m/s, SANS 10160-3). Any installation outside these limits needs reduced spacing.

Is there a non-penetrative tilt option?

Yes. It uses the Saflok 410/700 cleat, the Saflok 410/700 mini-rail clamp tilt support kit or the standing seam clamp kit. The clamp is accredited only on Saflok 700 and Saflok 410; for other sheets an on-site pull-out test is recommended.

Can the tilt legs go on a flat concrete roof?

Yes. Chemical anchors or expansion bolts may be required. Hole diameter, depth, curing time and tightening torque come from the anchor or bolt product datasheet.

How is the penetrative tilt base fixed?

With self-tapping screws into the metal or wooden purlins beneath the sheeting, through the holes on both sides of the base or through the centre hole, with EPDM rubber under the base. Purlin thickness must be 0.42 to 2.4 mm. Use a 3/8" hex socket at no more than 300 RPM.

All projects
Bloem Plaza, Bloemfontein: city blocks from directly above, with arrays on the rooftops
Bloem Plaza, Bloemfontein885.5 kWp, Free State
Other projects on this kit
ProjectSite typeProvince or countrySystem size
Village Baker, EswatiniRooftopEswatini215.6 kWp
ToyotaRooftopNot publishedNot published
KombatRooftopNot publishedNot published
Residential rooftop, new homeRooftop (residential)KwaZulu-NatalNot published

Quote a tilt mount kit

Send the roof or site, the system size and a layout if you have one. The quote request opens with tilt mount selected.